Dodge Journey: Description, Operation

DESCRIPTION

The generator is belt-driven by the engine. It is serviced only as a complete assembly. If the generator fails for any reason, the entire assembly must be replaced. The generator produces DC voltage.

OPERATION

As the energized rotor begins to rotate within the generator, the spinning magnetic field induces a current into the windings of the stator coil.

The Y type stator winding connections deliver the induced AC current to positive and negative diodes for rectification. From the diodes, rectified DC current is delivered to the vehicles electrical system through the generator, battery, and ground terminals.

Noise emitting from the generator may be caused by:

  • Worn, loose or defective bearings
  • Loose or defective drive pulley
  • Incorrect, worn, damaged or misadjusted drive belt
  • Loose mounting bolts
  • Misaligned drive pulley
  • Defective stator or diode
  • Damaged internal fins
    Generator
    ...

    Removal
    2.0L TURBO DIESEL Fig. 2: Generator Cables 1. Remove engine cover. 2. Disconnect and isolate the negative battery cable. 3. Remove accessory drive belt. 4. Disconnect battery cable fro ...

    See also:

    Manifold, exhaust, front
    Removal 1. Disconnect negative battery cable. 2. Remove the engine cover. Fig. 295: Oxygen Sensors 3. Disconnect and remove oxygen sensors (2) and (4). Fig. 296: Upper Maniverter Heat Shiel ...

    Uconnect™ Multimedia (SATELLITE RADIO) — IF EQUIPPED (REN/REQ/RER/RES/REU/RBZ RADIOS ONLY)
    Satellite radio uses direct satellite-to-receiver broadcasting technology to provide clear digital sound, coast to coast. The subscription service provider is Sirius Satellite Radio. This service o ...

    Duct, defroster
    REMOVAL WARNING: Disable the airbag system before attempting any steering wheel, steering column or instrument panel component diagnosis or service. Disconnect and isolate the negat ...

    0.2943