Dodge Journey: Description, Operation

DESCRIPTION

The generator is belt-driven by the engine. It is serviced only as a complete assembly. If the generator fails for any reason, the entire assembly must be replaced. The generator produces DC voltage.

OPERATION

As the energized rotor begins to rotate within the generator, the spinning magnetic field induces a current into the windings of the stator coil.

The Y type stator winding connections deliver the induced AC current to positive and negative diodes for rectification. From the diodes, rectified DC current is delivered to the vehicles electrical system through the generator, battery, and ground terminals.

Noise emitting from the generator may be caused by:

  • Worn, loose or defective bearings
  • Loose or defective drive pulley
  • Incorrect, worn, damaged or misadjusted drive belt
  • Loose mounting bolts
  • Misaligned drive pulley
  • Defective stator or diode
  • Damaged internal fins
    Generator
    ...

    Removal
    2.0L TURBO DIESEL Fig. 2: Generator Cables 1. Remove engine cover. 2. Disconnect and isolate the negative battery cable. 3. Remove accessory drive belt. 4. Disconnect battery cable fro ...

    See also:

    Description, Operation
    DESCRIPTION CAUTION: Grid lines can be damaged or scraped off with sharp instruments. Care should be taken in cleaning glass or removing foreign materials, decals or stickers. Normal glass ...

    Removal
    LEFT-HAND-DRIVE CAUTION: The vacuum in the power brake booster must be pumped down before removing the master cylinder to prevent the booster from sucking in any contamination. This ...

    Installation
    CAUTION: Be certain to adjust the refrigerant oil level when servicing the A/C refrigerant system. Failure to properly adjust the refrigerant oil level will prevent the A/C system fro ...