Dodge Journey: Diagnosis and testing
BATTERY
The battery must be completely charged and the terminals should be properly cleaned and inspected before diagnostic procedures are performed. See Cleaning for the proper battery cleaning procedures. See Inspection for the proper battery inspection procedures. Refer to Standard Procedure for the proper battery charging procedures.
MICRO 420 BATTERY TESTER (GASOLINE ENGINES)
The Micro 420 automotive battery tester is designed to help diagnose the cause of a defective battery. Follow the instruction service information supplied with the tester to properly diagnose a vehicle. If the instruction service information is not available refer to Standard Procedure , which includes the directions for using the Micro 420 battery tester.
OTC ONE STEP BATTERY ANALYZER AND CHARGER (DIESEL ENGINES)
The OTC One Step Battery Analyzer and Charger is designed to help diagnose the cause of a defective battery.
Follow the instruction information supplied with the tester to properly diagnose a vehicle.
WARNING: If the battery shows signs of freezing, leaking or loose posts, do not test, assist-boost, or charge. The battery may arc internally and explode.
Personal injury and/or vehicle damage may result.
WARNING: Explosive hydrogen gas forms in and around the battery. Do not smoke, use flame, or create sparks near the battery. Personal injury and/or vehicle damage may result.
WARNING: The battery contains sulfuric acid, which is poisonous and caustic. Avoid contact with the skin, eyes, or clothing. In the event of contact, flush with water and call a physician immediately. Keep out of the reach of children.
WARNING: Never exceed 14.4 volts when charging a spiral cell battery. Personal injury and/or battery damage may result.
A battery that will not accept a charge is faulty, and must be replaced. Further testing is not required. A fullycharged battery must be tested to determine its cranking capacity. A battery that is fully-charged, but fails the OTC One Step Battery Analyzer and Charger or other load test, is faulty and must be replaced.
NOTE: Completely discharged batteries may take several hours to accept a charge.
Refer to Standard Procedure for the proper battery charging procedures.
Description, Operation
DESCRIPTION
There are two different batteries available for this vehicle. Vehicles
equipped with a diesel engine utilize a
spiral cell battery with recombination technology. This is a maintenance- ...
Standard procedure
SPIRAL CELL BATTERY CHARGING
WARNING: Never exceed 14.4 volts when charging a spiral cell
battery. Personal
injury and/or battery damage may result.
Vehicles equipped with a diese ...
See also:
Installation
Fig. 474: Removing/Installing Valve Body
- VALVE BODY
NOTE: If valve body assembly is being replaced or reconditioned, it is
necessary to
perform the PCM Quick Learn Procedure.
1. ...
ROOF LUGGAGE RACK — IF EQUIPPED
The roof rack cross rails and side rails are designed to
carry cargo weight. The load must not exceed 150 lbs
(68 kg), and it should be distributed uniformly over the
cross rails. In addition, the ...
Cap, radiator
Description
Fig. 58: Cooling System Pressure Cap
- OVERFLOW NIPPLE
- MAIN SPRING
- GASKET RETAINER
- STAINLESS-STEEL SWIVEL TOP
- RUBBER SEALS
- VENT VALVE
- COOLANT OUTLET CONNECTO ...