Dodge Journey: Compressor, A/C

Standard procedure
REFRIGERANT SYSTEM SERVICE EQUIPMENT WARNING: Refer to the applicable warnings and cautions for this system before performing the following operation. Failure to follow these instructio ...

Description
FIXED DISPLACEMENT A/C COMPRESSOR Fig. 200: Denso 10SR17 Compressor NOTE: Denso 10SR17 shown. Denso 10SR15 similar. 2.7L and 3.5L 5-Passenger models are equipped with the Denso 10SR15 A/C ...

See also:

Refrigerant
DESCRIPTION The refrigerant used in this air conditioning system is a HydroFluoroCarbon (HFC), type R-134a. Unlike R-12, which is a ChloroFluoroCarbon (CFC), R-134a refrigerant does not contain ...

Ring(s), piston
Standard Procedure PISTON RING FITTING Fig. 200: CHECK GAP ON PISTON RINGS - FEELER GAUGE 1. Wipe cylinder bore clean. Insert ring and push down with piston to ensure it is square in bore ...

Module, steering column
DESCRIPTION Fig. 47: Steering Control Module This vehicle is equipped with a Steering Control Module (SCM) that is internal to the left multi-function switch housing (2). The left (lighting) mu ...

0.0105